Note for use of floor heating should not be underestimated

2019-09-03 12:56 admin
When the autumn wind gradually hit, the increasingly cool temperature reminds us that winter is coming. Many families use underfloor heating to keep their homes warmer. So heating season when using floor heating, what needs to pay attention to?
Floor heating is the most comfortable way of heating
The room room temperature of laid floor heating is bottom-up as the increase of height, temperature drops gradually, indoor surface temperature is even. This kind of temperature curve accords with the physiology demand of the person at the right moment, give a person the comfortable feeling with cold head of foot warm, in the meantime, ground warm can promote sufficient ministry blood circulation, improve systemic blood circulation thereby, promote metabolism.
The heat dissipation of floor heating is mainly concentrated in the height of human benefit, so the thermal efficiency is high. The circulating water for heating only needs to be between 40 and 50, and the indoor temperature can reach more than 20. In the past, a large number of heating pipes are exposed to the outside, and it is easy to hurt people when the temperature is too high, which affects the overall decoration style. However, floor heating reduces a large number of outdoor pipes, and indoor pipes are all encapsulated on the ground, so a lot of heat loss is reduced, and the phenomenon of high temperature at the top and low temperature at the bottom will not occur again.
After a long time, the floor heating is used again
Gradually increase the temperature
One to the heating season, there will always be due to non-standard installation and use of the floor heating safety accidents. So want to be safe and comfortable winter, winter floor heating should not be underestimated.
Although development business already checked when accepting a building, ground heating system is qualified, but the man-made damage that may appear during decorating, still can affect the normal operation of ground heating system. Therefore, before the first operation of the floor heating system, pressure test should be carried out on the pipeline system to see whether there is leakage, leakage and electricity phenomenon.
Any floor has the blemish that encounters heat to expand to be out of shape, because this USES when floor heating, must heat gradually. When the floor heating system is used again after a long time, it should be heated up strictly according to the heating procedure as it was used for the first time. The first time to use geothermal heating, heating in the first three days gradually increase: the first day water temperature 18, the second day 25, the third day 30, the fourth day can rise to 45. If the temperature rises too fast, the floor may crack and twist due to expansion. And use geothermal heating, ground surface temperature should not exceed 30, right now room temperature is in the environmental temperature that human body suits most 22 the following, the service life of the floor also can get safeguard.
In addition, during the operation of the floor heating system should regularly check whether the filter, valve, pressure gauge and other normal use, to ensure the safety of use.